Field Testing for Chlorine Dioxide Application Note

Document ID

Document ID CO347

Published Date

Published Date 01/16/2019
Print
 
Field Testing for Chlorine Dioxide Application Note
 
Chlorine dioxide (ClO2) may be used as either an oxidant or disinfectant in drinking water production. It is most frequently used as a pre-oxidant in conjunction with another disinfectant such as chlorine. Pre-oxidation with chlorine dioxide serves several treatment goals. Chlorine dioxide assists in the coagulation and removal of iron and manganese, oxidizes organic compounds without forming halogenated by-products, and is a potent disinfectant across a broad pH range.
When chlorine dioxide is used, it is essential that disinfectant and disinfectant by-product residual limits are not exceeded. The primary disinfection by-product of chlorine dioxide is chlorite (ClO2-). The US EPA maximum residual disinfectant level (MRDL) for chlorine dioxide is 0.8 mg/L at the entry point to the distribution system. Chlorite residuals most not exceed the maximum contaminant level (MCL) of 1.0 mg/L. The MRDL and MCL can be met through accurate dosing of chlorine dioxide as a pre oxidant. In addition, accurate dosing can ensure a small residual of disinfectant is maintained throughout the treatment process prior to primary disinfection.