Application Note : Danone Group Optimises TOC Management and Reduces Reagents Costs

Document ID

Document ID PR204

Published Date

Published Date 05/17/2022
Title
Application Note : Danone Group Optimises TOC Management and Reduces Reagents Costs
Overview
The treatment plant of a leading food products manufacturer historically depended on 1 daily laboratory sample to measure infl uent C/N/P loading to establish it’s chemical dosing regime. This snapshot result was not representative of daily fluctuations and did not over real time control. The installation of two BioTector analysers and a Real Time Controller Doser (RTC-DOS), specifi cally developed for the plant, provided real time measurement of incoming and outgoing organic loads, optimised management of the bu er tank, and automated the addition of nutrients. With the implementation of online analysers, the plant realised improved compliance on TOC/COD effluent values. They experienced a significant reduction in reagent consumption by 39% and saw an improvement in the quality of discharge with a reduction in overall nitrogen content of 48%.